Browsing Danish translation

Don't show this notice anymore
Before translating, be sure to go through Ubuntu Translators instructions and Danish guidelines.

These translations are shared with upstart 0.6 series template upstart.

14 of 4 results
118.
PRIORITY may be one of:
`debug' (messages useful for debugging upstart are logged, equivalent to --debug on kernel command-line);
`info' (messages about job goal and state changes, as well as event emissions are logged, equivalent to --verbose on the kernel command-line);
`message' (informational and debugging messages are suppressed, the default); `warn' (ordinary messages are suppressed whilst still logging warnings and errors);
`error' (only errors are logged, equivalent to --quiet on the kernel command-line) or
`fatal' (only fatal errors are logged).

Without arguments, this outputs the current log priority.
There are line breaks here. Each one represents a line break. Start a new line in the equivalent position in the translation.
There are leading/trailing spaces here. Each one represents a space character. Enter a space in the equivalent position in the translation.
(no translation yet)
Located in util/initctl.c:3246
126.
This command is intended to instruct the kernel to reboot or halt the system; when run without the -f option, or when in a system runlevel other than 0 or 6, it will actually execute /sbin/shutdown.
There are line breaks here. Each one represents a line break. Start a new line in the equivalent position in the translation.
(no translation yet)
Located in util/reboot.c:158
143.
TIME may have different formats, the most common is simply the word 'now' which will bring the system down immediately. Other valid formats are +m, where m is the number of minutes to wait until shutting down and hh:mm which specifies the time on the 24hr clock.

Logged in users are warned by a message sent to their terminal, you may include an optional MESSAGE included with this. Messages can be sent without actually bringing the system down by using the -k option.

If TIME is given, the command will remain in the foreground until the shutdown occurs. It can be cancelled by Control-C, or by another user using the -c option.

The system is brought down into maintenance (single-user) mode by default, you can change this with either the -r or -h option which specify a reboot or system halt respectively. The -h option can be further modified with -H or -P to specify whether to halt the system, or to power it off afterwards. The default is left up to the shutdown scripts.
There are line breaks here. Each one represents a line break. Start a new line in the equivalent position in the translation.
(no translation yet)
Located in util/shutdown.c:246
163.
RUNLEVEL should be one of 0123456sS, where s and S are considered identical.

RUNLEVEL may also be Q or q to instruct the init daemon to reload its configuration, this is rarely necessary since the daemon watches its configuration for changes.

RUNLEVEL may be U or u to instruct the init daemon to re-execute itself, this is not recommended since Upstart does not currently preserve its state.
There are line breaks here. Each one represents a line break. Start a new line in the equivalent position in the translation.
(no translation yet)
Located in util/telinit.c:218
14 of 4 results

This translation is managed by De danske oversættere af Ubuntu, assigned by Ubuntu Translators.

You are not logged in. Please log in to work on translations.

Contributors to this translation: AJenbo, Aputsiak Niels Janussen, Ask Hjorth Larsen, Joe Hansen, Louis, Mads Thomsen.